Closed-Loop Scanner Series“ — ScannerXX.Ultra

Scanners with sub-nanoscale resolution capacitive displacement sensors for closed-loop control

 

Precision demands a sensor.

Closed-loop scanner with a displacement sensor actively compensates the negative effects such as environment temperature drift, piezoelectric creep and self-heating, achieving unprecedented precision at low temperatures, which ensures the sophisticated experiments survive at extreme low temperature.

 

 

“25 mm” Series

• Scanner25-x.Ultra

• Scanner25-x.Ultra.UHV

• Scanner25-x.Ultra.ULT

• Scanner25-x.Ultra.UHV.ULT

• Scanner25-z.Ultra

• Scanner25-z.Ultra.UHV

• Scanner25-z.Ultra.ULT

• Scanner25-z.Ultra.UHV.ULT

“35 mm” Series

• Scanner35-xy.Ultra

• Scanner35-xy.Ultra.UHV

• Scanner35-xy.Ultra.ULT

• Scanner35-xy.Ultra.UHV.ULT

• Scanner35-z.Ultra

• Scanner35-z.Ultra.UHV

• Scanner35-z.Ultra.ULT

• Scanner35-z.Ultra.UHV.ULT

 

Default version, compatible with 1E-7 mbar

ULT version, used at He3 or dilution cryogenics systems

UHV version, compatible with 2E-11 mbar

 

Precision, Spacial Resolution & Repeatability

 

Precision, also known Standard Deviation ( ISO 3534-2:2006 )

Precision is the closeness of agreement between independent test results obtained under stipulated conditions. The measure of precision is usually expressed in terms of imprecision and computed as a standard deviation of the test results. Less precision is reflflected by a larger standard deviation. [SOURCE: ISO 3534-2:2006,3.3.4]

 

Spacial Resolution, discussion about the criterion

Resolution is generally defifined as the smallest detectable interval between measured values. For a physical parameter whose measurement values follow a Gaussian distribution N (μ, σ2), a signifificant portion of people equate the standard deviation σ directly with resolution, while others adopt a stricter criterion, such as 3σ. When the measured values are adjacent, the percentage of overlapping area between their Gaussian distributions determines the distinguishability of these two values, which is a critical factor in defifining the resolution.

 

 

 

Example, Spacial resolution of Scanner.Ultra motion

Scanner35-z.Ultra was operated at 4.2 K in a ultra low-vibration cryogenic platform (ColdTABLE*) . The data acquisition from the capacitive sensor showed the RMS noise (σ) during closed-loop control was typically ~0.4 nm. We make scanner to move step by step with 1 nm distance. It is easy to distinguish steps.

 

 

Characterization of Bidirectional Repeatability ( ISO 230-2:2006(E) )

The bidirectional repeatability characterization was performed using a laser interferometer (resolution 0.1 nm, sampling rate 50 kHz) to monitor the displacement of scanner. The scanner was programmed to execute bidirectional motion over a 30 um range with 3 um incremental steps ( 20 steps in one cycle ), completing 10 full back- and-forth cycles. The experiments was performed at 4.2 K in a ultra low-vibration cryogenic platform (ColdTABLE) with a MC-ArchimedesLT.Ultra03 controller. The positioning deviation were calculated as Eij = Pmeasure,ij — Pmean,i, where i denotes the target position index and j denotes the cycle number. The fifigure below shows all position deviation in ±5 nm range. According to the defifinition of bidirectional repeatability in ISO 230-2:2006(E) , the bidirectional repeatability of Scanner.Ultra series product is smaller than 5 nm. All parameters MultiFields shows in specifification strictly follow ISO 230-2:2006(E).

 

 

 

The sensor redefifines the motion control at cryogenic temperature

 

Our proprietary capacitive displacement sensor delivers subnanometer resolution in cryogenic environments — the core reason why our scanner achieves excellent precision, resolution and repeatability.

Capacitive displacement sensor C0.2.FLT.Cryo

 

New Controller - MC-ArchimedesLT.03.Ultra

Multi-channels high-speed controller for closed-loop scanner control

 

Features

 

Capacitive sensing Sub-nm displacement resolution | Tunable analog bandwidth
High-speed Data acquisition 50 kSa/s sampling rate | Synchronous multi-channel sampling
Real-time communication SPI communication between master and slave | 50 kSa/s stable data transmission | EtherCAT/ EtherNET/ USB3.0
Closed-loop control Sub-nm resolution at ultra-high speed | Synchronous multi-channel closed-loop control

 

Interface & Functions

 

Communications Drive terminals Sensing terminals

* EtherCAT

* EtherNET

* USB 3.0

* Analog in

* Analog out

* Trigger in

* Trigger out

* Voltage Output

* Sensor input

* Tuning Knob

* Analog out

 

 

 

 

Figure.3 Closed- loop scanner controller - MC-ArchimedesLT.03.Ultra. Working together with Multififields® closed-loop scanner , each of three channels maintains synchronous and individual closed-loop control with sub-nm resolution.

 

 

 

 

Scanner25-x.Ultra

Features • Closed-loop control • 55 um travel range at room temperature • Ultra-high vacuum & low temperature compatible
  • Sub-nm resolution    

 

Picture & dimensions

 

 

 

Specififications

 

 

 

Scanner25-z.Ultra

 

Features • Closed-loop control • 55 um travel range at room temperature • Ultra-high vacuum & low temperature compatible
  • Sub-nm resolution    

 

Picture & dimensions

 

 

 

Specififications

 

 

 

Scanner35-xy.Ultra

 

Features • Closed-loop control • 100 × 100 um travel range at room temperature • Ultra-high vacuum & low temperature compatible
  • Sub-nm resolution    

 

 

Picture & dimensions

 

 

Specififications

 

 

Scanner35-z.Ultra

 

Features • Closed-loop control • 100 um travel range at room temperature • Ultra-high vacuum & low temperature compatible
  • Sub-nm resolution    

 

 

Picture & dimensions

 

Specififications

 

 

 